{"id":3113,"date":"2018-05-02T19:20:45","date_gmt":"2018-05-02T19:20:45","guid":{"rendered":"https:\/\/metrologija.digitalcontrol.me\/?page_id=3113"},"modified":"2025-10-14T10:50:39","modified_gmt":"2025-10-14T09:50:39","slug":"laboratorija-za-elektricne-velicine","status":"publish","type":"page","link":"https:\/\/metrologija.me\/en\/laboratorija-za-elektricne-velicine\/","title":{"rendered":"Laboratory for Electrical Quantities"},"content":{"rendered":"<p><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-2 nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\"  style='background-color: rgba(255,255,255,0);background-position: center center;background-repeat: no-repeat;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;'><div class=\"fusion-builder-row fusion-row \"><div  class=\"fusion-layout-column fusion_builder_column fusion_builder_column_1_1 fusion-builder-column-1 fusion-one-full fusion-column-first fusion-column-last 1_1\"  style='margin-top:10px;margin-bottom:10px;'><div class=\"fusion-column-wrapper\" style=\"padding: 0px 0px 0px 0px;background-position:left top;background-repeat:no-repeat;-webkit-background-size:cover;-moz-background-size:cover;-o-background-size:cover;background-size:cover;\"   data-bg-url=\"\"><div class=\"fusion-tabs fusion-tabs-2 classic vertical-tabs icon-position-left\"><style type=\"text\/css\">.fusion-tabs.fusion-tabs-2 .nav-tabs li a.tab-link{border-top-color:#faf9f8;background-color:#faf9f8;}.fusion-tabs.fusion-tabs-2 .nav-tabs{background-color:#ffffff;}.fusion-tabs.fusion-tabs-2 .nav-tabs li.active a.tab-link,.fusion-tabs.fusion-tabs-2 .nav-tabs li.active a.tab-link:hover,.fusion-tabs.fusion-tabs-2 .nav-tabs li.active a.tab-link:focus{border-right-color:#ffffff;}.fusion-tabs.fusion-tabs-2 .nav-tabs li.active a.tab-link,.fusion-tabs.fusion-tabs-2 .nav-tabs li.active a.tab-link:hover,.fusion-tabs.fusion-tabs-2 .nav-tabs li.active a.tab-link:focus{background-color:#ffffff;}.fusion-tabs.fusion-tabs-2 .nav-tabs li a:hover{background-color:#ffffff;border-top-color:#ffffff;}.fusion-tabs.fusion-tabs-2 .tab-pane{background-color:#ffffff;}.fusion-tabs.fusion-tabs-2 .nav,.fusion-tabs.fusion-tabs-2 .nav-tabs,.fusion-tabs.fusion-tabs-2 .tab-content .tab-pane{border-color:#ede8e8;}<\/style><div class=\"nav\"><ul class=\"nav-tabs\"><li class=\"active\"><a class=\"tab-link\" data-toggle=\"tab\" id=\"fusion-tab-activities\" href=\"#tab-7994a5c3a1af49a835f\"><h4 class=\"fusion-tab-heading\">ACTIVITIES<\/h4><\/a><\/li><li><a class=\"tab-link\" data-toggle=\"tab\" id=\"fusion-tab-nationalmeasurementstandard\" href=\"#tab-4a15af42a8cc34e049b\"><h4 class=\"fusion-tab-heading\">NATIONAL MEASUREMENT STANDARD<\/h4><\/a><\/li><li><a class=\"tab-link\" data-toggle=\"tab\" id=\"fusion-tab-calibrationofmeasurementstandards\" href=\"#tab-6e1917d6c44936249c3\"><h4 class=\"fusion-tab-heading\">CALIBRATION OF MEASUREMENT STANDARDS<\/h4><\/a><\/li><li><a class=\"tab-link\" data-toggle=\"tab\" id=\"fusion-tab-scopeofaccreditation\" href=\"#tab-d6e5e4fd6762ff2e182\"><h4 class=\"fusion-tab-heading\">SCOPE OF ACCREDITATION<\/h4><\/a><\/li><li><a class=\"tab-link\" data-toggle=\"tab\" id=\"fusion-tab-verificationofmeasuringinstruments\" href=\"#tab-ab12d7e8a39833a2723\"><h4 class=\"fusion-tab-heading\">VERIFICATION OF MEASURING INSTRUMENTS<\/h4><\/a><\/li><li><a class=\"tab-link\" data-toggle=\"tab\" id=\"fusion-tab-typeapprovalofmeasuringinstruments\" href=\"#tab-00ef44aef8287b2484d\"><h4 class=\"fusion-tab-heading\">TYPE APPROVAL OF MEASURING INSTRUMENTS <\/h4><\/a><\/li><li><a class=\"tab-link\" data-toggle=\"tab\" id=\"fusion-tab-traceabilityscheme\" href=\"#tab-80ae5f12603f7b5bcdc\"><h4 class=\"fusion-tab-heading\">TRACEABILITY SCHEME<\/h4><\/a><\/li><li><a class=\"tab-link\" data-toggle=\"tab\" id=\"fusion-tab-contact\" href=\"#tab-c500d80405b9fdd133f\"><h4 class=\"fusion-tab-heading\">CONTACT<\/h4><\/a><\/li><\/ul><\/div><div class=\"tab-content\"><div class=\"nav fusion-mobile-tab-nav\"><ul class=\"nav-tabs\"><li class=\"active\"><a class=\"tab-link\" data-toggle=\"tab\" id=\"mobile-fusion-tab-activities\" href=\"#tab-7994a5c3a1af49a835f\"><h4 class=\"fusion-tab-heading\">ACTIVITIES<\/h4><\/a><\/li><\/ul><\/div><div class=\"tab-pane fade fusion-clearfix in active\" id=\"tab-7994a5c3a1af49a835f\">\n<h3>Activities<\/h3>\n<p>The Laboratory for Electrical Quantities carries out the tasks related to:<\/p>\n<ul>\n<li>realization, preservation, maintenance and improvement of the national standard of electrical quantitites in Montenegro;<\/li>\n<li>providing metrological traceability in the area of electrical quantities in Montenegro by transferring the unit of electrical quantities from the national standard to the secondary and working standards;<\/li>\n<li>development of measurement methods for transferring the unit of electrical quantities;<\/li>\n<li>calibration of measuring instruments\/standards used for measuring electrical quantities;<\/li>\n<li>participation in inter-laboratory comparisons;<\/li>\n<li>verification of devices used for measuring electrical quantities.<\/li>\n<\/ul>\n<\/div><div class=\"nav fusion-mobile-tab-nav\"><ul class=\"nav-tabs\"><li><a class=\"tab-link\" data-toggle=\"tab\" id=\"mobile-fusion-tab-nationalmeasurementstandard\" href=\"#tab-4a15af42a8cc34e049b\"><h4 class=\"fusion-tab-heading\">NATIONAL MEASUREMENT STANDARD<\/h4><\/a><\/li><\/ul><\/div><div class=\"tab-pane fade fusion-clearfix\" id=\"tab-4a15af42a8cc34e049b\">\n<h3>National Measurement Standard<\/h3>\n<p>National measurement standard is a digital multimeter, manufactured by FLUKE, type 8508A. With a 8,5-digit resolution, exceptional linearity and low noise level, FLUKE 8508A digital multimeter ensures the most accurate measurements of commercially available measuring instruments today in the field of voltage, current and resistance measurements. In addition to the accuracy of the multimeter, its stability is also very important. FLUKE 8508A multimeter ensures long-term stability of 2,7 ppm, and short-term stability of 0,5 ppm, assuring confidence in measurement throughout the whole year.<\/p>\n<p>FLUKE 8508A multimeter replaces 8 measuring instruments:<\/p>\n<ul>\n<li>multimeter<\/li>\n<li>measuring bridge for measuring electrical resistance<\/li>\n<li>voltage divider<\/li>\n<li>null detector<\/li>\n<li>AC\/DC transfer<\/li>\n<li>thermometer<\/li>\n<li>AC\/DC resistors<\/li>\n<li>picoammeter<\/li>\n<\/ul>\n<p>The FLUKE 8508A multimeter with measuring range from 200 mV to 1 kV for measuring voltage, and the frequency range up to 1 MHz for AC measurement, cover all low frequency voltage measurements. All ranges aloow 8.5-digit resolution. The exceptional linearity, combined with the ratio measurement possiblity, results in the FLUKE 8508A multimeter being able to replace the use of Kelvin Varley dividers and AC\/DC voltage transfer standards. Current measurement ranges from 200 \u03bcA to 20 A at frequencies from 1 Hz to 100 kHz for AC measurement. The FLUKE 8508A multimeter can measure resistance in the range of 2 \u03a9 to 20 G\u03a9, with a possiblity of 5.5 to 8.5 digit resolution.<\/p>\n<\/div><div class=\"nav fusion-mobile-tab-nav\"><ul class=\"nav-tabs\"><li><a class=\"tab-link\" data-toggle=\"tab\" id=\"mobile-fusion-tab-calibrationofmeasurementstandards\" href=\"#tab-6e1917d6c44936249c3\"><h4 class=\"fusion-tab-heading\">CALIBRATION OF MEASUREMENT STANDARDS<\/h4><\/a><\/li><\/ul><\/div><div class=\"tab-pane fade fusion-clearfix\" id=\"tab-6e1917d6c44936249c3\">\n<h3>Calibration Of Measurement Standards<\/h3>\n<h3>Accredited area<\/h3>\n<p>Calibration of calibrators (voltage, current and resistance sources) in the range:<\/p>\n<ul>\n<li>DC voltage in the range from 0 mV to 1000 V;<\/li>\n<li>AC voltage in the range from 100 mV to 200 V (50 Hz \u2013 100 kHz), from 200 mV to 2V (100kHz to 1 MHz), from 2 V to 20 V (100 kHz \u2013 500 kHz), from 200V to 700 V (50 Hz \u2013 1 kHz)<\/li>\n<li>DC current in the range from 0,1 mA to 10 A;<\/li>\n<li>AC current in the range from 0,1 mA to 0,2 mA (50 Hz \u2013 1 kHz), from 0,2 mA to<\/li>\n<li>10 A (45 Hz \u2013 10 kHz);<\/li>\n<li>Resistance in the range from 1\u03a9 to 100 M\u03a9.<\/li>\n<\/ul>\n<p>Calibration of multimeters in the range:<\/p>\n<ul>\n<li>DC voltage in the range from 0mV to 1000 V;<\/li>\n<li>AC voltage in the range from 100 mV to 200 V (50 Hz \u2013 100 kHz) and from 200 mV to<\/li>\n<li>2 V (100 kHz \u2013 1 MHz); from 2 V to 20 V (100 kHz \u2013 500 kHz), from 200V to 700V (50 Hz \u2013 1 kHz);<\/li>\n<li>DC current in the range from 0,1 mA do 10 A;<\/li>\n<li>AC current in the range from 0,1 mA to 0,2 mA (50 Hz \u2013 1 kHz), from 0,2 mA to 10 A (45 Hz \u2013 10 kHz);<\/li>\n<li>Resistance in the range from 1\u03a9 to 100 M\u03a9.<\/li>\n<\/ul>\n<h3>Unaccredited area:<\/h3>\n<p>Calibration of clamp meters in:<\/p>\n<ul>\n<li>DC voltage in the range from 0mV to 600 V;<\/li>\n<li>AC voltage in the range from 100 mV to 600 V (50 Hz);<\/li>\n<li>DC current in the range from 0,1 mA to 500 A;<\/li>\n<li>AC current in the range from 0,1 mA to 500 A (50 Hz);<\/li>\n<li>Resistance in the range from 1\u03a9 to 40 M\u03a9.<\/li>\n<\/ul>\n<\/div><div class=\"nav fusion-mobile-tab-nav\"><ul class=\"nav-tabs\"><li><a class=\"tab-link\" data-toggle=\"tab\" id=\"mobile-fusion-tab-scopeofaccreditation\" href=\"#tab-d6e5e4fd6762ff2e182\"><h4 class=\"fusion-tab-heading\">SCOPE OF ACCREDITATION<\/h4><\/a><\/li><\/ul><\/div><div class=\"tab-pane fade fusion-clearfix\" id=\"tab-d6e5e4fd6762ff2e182\">\n<h3>Scope Of Accreditation<\/h3>\n<h3><a href=\"https:\/\/metrologija.me\/wp-content\/uploads\/akreditacija\/2019\/ATCG_elektricne.pdf\"><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-2963\" src=\"https:\/\/metrologija.me\/wp-content\/uploads\/2018\/04\/ATCG.jpg\" alt=\"\" width=\"250\" height=\"360\" \/><\/a><a href=\"https:\/\/metrologija.me\/wp-content\/uploads\/akreditacija\/2019\/HAA_elektricne.pdf\"><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-2964\" src=\"https:\/\/metrologija.me\/wp-content\/uploads\/2018\/04\/HAA.jpg\" alt=\"\" width=\"254\" height=\"360\" \/><\/a><\/h3>\n<\/div><div class=\"nav fusion-mobile-tab-nav\"><ul class=\"nav-tabs\"><li><a class=\"tab-link\" data-toggle=\"tab\" id=\"mobile-fusion-tab-verificationofmeasuringinstruments\" href=\"#tab-ab12d7e8a39833a2723\"><h4 class=\"fusion-tab-heading\">VERIFICATION OF MEASURING INSTRUMENTS<\/h4><\/a><\/li><\/ul><\/div><div class=\"tab-pane fade fusion-clearfix\" id=\"tab-ab12d7e8a39833a2723\">\n<h3>Verification Of Measuring Instruments<\/h3>\n<p style=\"text-align: justify;\">The Laboratory for Electrical Quantities carries out examination of measuring instruments used for testing safety measures in electrical engineering with the aim of their verification.<\/p>\n<\/div><div class=\"nav fusion-mobile-tab-nav\"><ul class=\"nav-tabs\"><li><a class=\"tab-link\" data-toggle=\"tab\" id=\"mobile-fusion-tab-typeapprovalofmeasuringinstruments\" href=\"#tab-00ef44aef8287b2484d\"><h4 class=\"fusion-tab-heading\">TYPE APPROVAL OF MEASURING INSTRUMENTS <\/h4><\/a><\/li><\/ul><\/div><div class=\"tab-pane fade fusion-clearfix\" id=\"tab-00ef44aef8287b2484d\">\n<h3>Type Approval Of Measuring Instruments<\/h3>\n<p>In order to examine compliance with the prescribed technical and metrological requirements to determine the type of a measuring instrument, the Laboratory for Electrical Quantities carries out type examination for measuring instruments used for testing safety measures in electrical engineering in accordance with the Decree on legal measuring instruments that are subject to mandatory verification or type approval (Official Gazette of Montenegro 81\/09).<\/p>\n<ul>\n<li>Measuring instruments for testing safety measures in electrical engineering.<\/li>\n<\/ul>\n<\/div><div class=\"nav fusion-mobile-tab-nav\"><ul class=\"nav-tabs\"><li><a class=\"tab-link\" data-toggle=\"tab\" id=\"mobile-fusion-tab-traceabilityscheme\" href=\"#tab-80ae5f12603f7b5bcdc\"><h4 class=\"fusion-tab-heading\">TRACEABILITY SCHEME<\/h4><\/a><\/li><\/ul><\/div><div class=\"tab-pane fade fusion-clearfix\" id=\"tab-80ae5f12603f7b5bcdc\">\n<h3>Traceability Scheme<\/h3>\n<p style=\"text-align: justify;\">Laboratorija za elektri\u010dne veli\u010dine ostvaruje sljedivost preko digitalnog multimetra, proizvo\u0111a\u010da FLUKE, tip 8508A. Laboratorija za elektri\u010dne veli\u010dine eksterne kalibracije svojih referentnih etalona i opreme obavlja u laboratorijama nacionalnih metrolo\u0161kih instituta ili ovla\u0161\u0107enih instituta (EURAMET Designated Institutes) koji imaju objavljen CMC u bazi podataka BIPM \u2013 a ili su akreditovane od strane akreditacionog tijela potpisnika EA MLA sporazuma.<\/p>\n<p><a href=\"https:\/\/metrologija.me\/wp-content\/uploads\/akreditacija\/sema_eng_LEQ.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-10546 size-fusion-400\" src=\"https:\/\/metrologija.me\/wp-content\/uploads\/akreditacija\/sema_eng_LEQ-400x566.jpg\" alt=\"\" width=\"400\" height=\"566\" srcset=\"https:\/\/metrologija.me\/wp-content\/uploads\/akreditacija\/sema_eng_LEQ-200x283.jpg 200w, https:\/\/metrologija.me\/wp-content\/uploads\/akreditacija\/sema_eng_LEQ-212x300.jpg 212w, https:\/\/metrologija.me\/wp-content\/uploads\/akreditacija\/sema_eng_LEQ-400x566.jpg 400w, https:\/\/metrologija.me\/wp-content\/uploads\/akreditacija\/sema_eng_LEQ-600x849.jpg 600w, https:\/\/metrologija.me\/wp-content\/uploads\/akreditacija\/sema_eng_LEQ-724x1024.jpg 724w, https:\/\/metrologija.me\/wp-content\/uploads\/akreditacija\/sema_eng_LEQ-768x1086.jpg 768w, https:\/\/metrologija.me\/wp-content\/uploads\/akreditacija\/sema_eng_LEQ-800x1131.jpg 800w, https:\/\/metrologija.me\/wp-content\/uploads\/akreditacija\/sema_eng_LEQ-1086x1536.jpg 1086w, https:\/\/metrologija.me\/wp-content\/uploads\/akreditacija\/sema_eng_LEQ.jpg 1200w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" \/><\/a><\/p>\n<\/div><div class=\"nav fusion-mobile-tab-nav\"><ul class=\"nav-tabs\"><li><a class=\"tab-link\" data-toggle=\"tab\" id=\"mobile-fusion-tab-contact\" href=\"#tab-c500d80405b9fdd133f\"><h4 class=\"fusion-tab-heading\">CONTACT<\/h4><\/a><\/li><\/ul><\/div><div class=\"tab-pane fade fusion-clearfix\" id=\"tab-c500d80405b9fdd133f\">\n<h3>Contact<\/h3>\n<p><strong>Head of Laboratory:<br \/>\n<\/strong>Dejan Soki\u0107, Graduate Degree in Engineering<br \/>\ntel: +382 20 601 360<br \/>\n+382 20 601 361<br \/>\nfax: +382 20 634 651<br \/>\ne-mail:\u00a0<a href=\"mailto:dejan.sokic@metrologija.gov.me\">dejan.sokic@metrologija.gov.me<\/a><\/p>\n<p><strong>Deputy Head of Laboratory:<br \/>\n<\/strong>Milan Perovi\u0107, Spec. App.<br \/>\ntel: +382 20 601 360<br \/>\n+382 20 601 361<br \/>\nfax: +382 20 634 651<br \/>\ne-mail:\u00a0<a href=\"mailto:milan.perovic@metrologija.gov.me\">milan.perovic@metrologija.gov.me<\/a><\/p>\n<\/div><\/div><\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><\/div><\/div><\/p>","protected":false},"excerpt":{"rendered":"","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-3113","page","type-page","status-publish","hentry"],"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/metrologija.me\/en\/wp-json\/wp\/v2\/pages\/3113","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/metrologija.me\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/metrologija.me\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/metrologija.me\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/metrologija.me\/en\/wp-json\/wp\/v2\/comments?post=3113"}],"version-history":[{"count":24,"href":"https:\/\/metrologija.me\/en\/wp-json\/wp\/v2\/pages\/3113\/revisions"}],"predecessor-version":[{"id":18803,"href":"https:\/\/metrologija.me\/en\/wp-json\/wp\/v2\/pages\/3113\/revisions\/18803"}],"wp:attachment":[{"href":"https:\/\/metrologija.me\/en\/wp-json\/wp\/v2\/media?parent=3113"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}